Der SR50AT ist ein Ultraschall-Distanzsensor, der aus der Zeit zwischen der Emission und der Rückkehr des Ultraschallpulses den Abstand zu einer Oberfläche bestimmt. So kann man Schnee- oder Wasserpegelhöhe messen. Der SR50AT enthält einen integrierten Temperatursensor und gibt einen temperaturkorrigierten Wert aus.
Note: Campbell Scientific empfiehlt Modell SR50AT-316SS-L für den Einsatz in mariner Umgebung.
Lesen Sie mehrThe SR50AT is an identical unit to the SR50A with the addition of an external temperature sensor. The temperature sensor requires a six-plate radiation shield. The SR50AT will output a temperature-corrected distance reading, eliminating the need for further post-processing, as well as a separate temperature reading.
The SR50AT was designed to meet the stringent requirements of measuring snow depths and uses a multiple echo processing algorithm to help ensure measurement reliability. The SR50AT is compatible with all current Campbell Scientific data loggers, as well as many other data acquisition systems. An air temperature measurement is required to correct for variations of the speed of sound in air. Either the SR50AT or an existing on-site air temperature sensor can be used. The SR50AT is available with a heater option for locations where rime ice is a problem.
Measurement Time | < 1.0 s |
Output Options | SDI-12 version 1.3, RS-232, RS-485 (output options selected by configuring internal jumpers) |
Baud Rates | 1200 to 38400 bps (RS-232, RS-485 modes) |
Power Requirements | 9 to 18 Vdc (typically powered by data logger’s 12 Vdc power supply) |
Measurement Range | 0.5 to 10 m (1.6 to 32.8 ft) |
Beam Acceptance Angle | ~30° |
Resolution | 0.25 mm (0.01 in.) |
Accuracy | ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest). |
Operating Temperature Range | -45° to +50°C |
Compliance | CE compliant |
Temperature Accuracy |
|
Cable Type | 4 conductor, 2-twisted pair, 22 AWG, Santoprene |
Diameter | 7.6 cm (3 in.) |
Length | 10.1 cm (4 in.) |
Weight | 375 g (13.2 oz) without cable |
Cable Weight | 250 g (8.2 oz) for a 4.57-m (15-ft) cable |
Power Consumption |
|
Active | 250 mA (typical) |
Quiescent SDI-12 Mode | < 1.0 mA The quiescent current draw is less than 1.25 mA if the BAUD rate is 9600 BAUD or less |
RS-232/RS-485 Mode | < 2.0 mA |
Maximum Cable Length |
|
-NOTE- | Cable lengths greater than 60 m require a heavier gage wire if the power supply drops below 11 Vdc. |
SDI-12 | 60 m (200 ft) |
RS-232 | 60 m (200 ft) 9600 BAUD or less |
RS-485 | 300 m (984 ft) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR1000X | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR300 (retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR3000 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR310 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR350 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR6 | SDI-12, RS-232, and RS-485 | |
CR800 (retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR850 (retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
Product | Compatible | Note |
---|---|---|
GRANITE 6 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
One single-ended channel per probe is required; an excitation channel can be shared by several probes.
CR6 and CR1000X programs that directly read each type of SR50AT output (SDI-12, RS-232, RS-485), and a CR1000 program that reads the RS-485 output using an MD485 Multidrop interface. The programs use the data filtering method described in the manual.