SR50A-EE-L Anodized Sonic Distance Sensor for Extreme Environments
Rugged
Corrosion-resistant chassis and transducer
wetter  wasser  energie  gas flux and turbulence  bauwerke  boden

Überblick

The SR50A-EE is an anodized version of Campbell Scientific's acoustic sensor for measuring the distance from the sensor to the snow surface. The sensor has been designed to operate in extreme environmental conditions where corrosion is a concern (such as coastal regions). The SR50A-EE features an aluminum body that has been treated with a Type III, hard-anodizing process (MIL-A-8625 Type III) that delivers best-in-class corrosion and wear resistance.

To properly calculate snow depth from the measured distance, an air temperature measurement is required to correct for variations of the speed of sound in air. This sensor is compatible with most Campbell Scientific data loggers.

Lesen Sie mehr

Funktionen und Vorteile

  • Type III, hard-anodized body for increased resistance to corrosion and wear
  • Open-faced transducer for increased corrosion resistance and decreased maintenance
  • Non-contact method for determining snow depth
  • Wide operating temperature range
  • Designed for coastal or corrosive environments
  • User-selectable options for output
  • Uses a multiple echo processing algorithm to help ensure measurement reliability
  • Compatible with most Campbell Scientific data loggers

Bilder

Technische Beschreibung

The SR50A-EE was designed to meet the stringent requirements of measuring depths and uses a multiple echo processing algorithm to help ensure measurement reliability.

SDI-12, RS-232, and RS-485 output options are available for measuring the SR50A-EE. Campbell Scientific’s MD485 interface can be used to connect one or more SR50A-EE sensors in RS-485 mode to an RS-232 device. This can be useful for sensors that require lead lengths that exceed the limits of either RS-232 or SDI-12 communications. The SR50AH-L is available with a heater option for locations where rime ice is a problem.

Spezifikationen

Measurement Time < 1.0 s
Output Options SDI-12 version 1.3, RS-232, RS-485 (output options selected by configuring internal jumpers)
Baud Rates 1200 to 38400 bps (RS-232, RS-485 modes)
Power Requirements 9 to 18 Vdc (typically powered by data logger’s 12 Vdc power supply)
Measurement Range 0.5 to 10 m (1.6 to 32.8 ft)
Beam Acceptance ~30°
Resolution 0.25 mm (0.01 in.)
Accuracy ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest). Requires external temperature compensation.
Operating Temperature Range -45° to +50°C
Compliance CE compliant
Length 10.1 cm (4.0 in.)
Diameter 7.5 cm (3 in.)
Weight 362.9 g (12.8 oz) without cable
Cable Weight 250 g (8.2 oz) for a 4.57-m (15-ft) cable

Maximum Cable Length

-NOTE- Cable lengths greater than 60 m require a heavier gage wire if the power supply drops below 11 Vdc.
SDI-12 60 m (200 ft)
RS-232 60 m (200 ft)
Baud rates ≤ 9600 bps
RS-485 300 m (984 ft)

Power Consumption

Active 250 mA (typical)
Quiescent SDI-12 Mode < 1.0 mA
Quiescent RS-232/RS-485 Modes
  • < 1.25 mA (≤ 9600 bps)
  • < 2.0 mA (> 9600 bps)

Kompatibel mit

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Datenlogger

Product Compatible Note
CR1000 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR1000X SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR300 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR3000 SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR310 SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR350 SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR6 SDI-12, RS-232, and RS-485
CR800 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR850 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.

Miscellaneous

Product Compatible Note
GRANITE 6 SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.

Additional Compatibility Information

Data Logger Considerations

One single-ended channel per probe is required; an excitation channel can be shared by several probes.

Downloads

SR50A example programs v.1 (11 kB) 22-01-2020

CR6 and CR1000X programs that directly read each type of SR50A output (SDI-12, RS-232, RS-485), and a CR1000 program that reads the RS-485 output using an MD485 Multidrop interface. A 107 sensor provides the temperature measurement needed for temperature compensation. The programs use the data filtering method described in the manual.