The A21REL-12 contains four internal relays that allow a Campbell Scientific datalogger to control up to four external ac or dc devices.
Lesen Sie mehrThe A21REL-12's internal relays are single-pole double-throw. This relay driver may be powered by the datalogger power supply or a separate 12 Vdc battery.
Function | Allows a data logger to control up to four external ac or dc devices. |
Number of Channels | 4 |
Contact Ratings |
|
Coil Current | 13 mA/relay |
Relays | dual single-pole, double-throw relays |
Operating Temperature | -25° to +50°C |
Operating Voltage | 12 Vdc |
Dimensions | 14.0 x 6.9 x 3.0 cm (5.5 x 2.7 x 1.2 in.) |
Weight | 227 g (8 oz) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR200X (retired) | ||
CR216X (retired) | ||
CR300 (retired) | ||
CR3000 | ||
CR310 | ||
CR350 | ||
CR5000 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000X (retired) |
Each of the four relays is controlled by a data logger control port.
Cable(s) Used | Number of Relays Controlled |
One CABLE3CBL-L | 1 |
One CABLE4CBL-L | 2 |
One CABLE5CBL-L | 3 |
Two CABLE3CBL-L | 4 |
The A21REL-12 may be powered by the data logger power supply or a separate 12 Vdc battery.
The A21REL-12 requires a non-condensing environment. No mounting bracket is available. The peripheral is typically mounted in the data logger enclosure with double-sided tape or Velcro.
Number of FAQs related to A21REL-12: 1
The following relay devices can be used with the CR800 and the CR850:
The CR800 and the CR850 can also be used with a wide variety of third-party relay devices.
*Because the CR800 and the CR850 only have four digital ports, they do not have the ability to switch all six of the relays on the A6REL-12.