Das Enc14/16 ist ein wetterfestes Gehäuse, 35,6cm breit und 40,6 cm hoch. Es kann Datenlogger, Stromversorgung und ein oder mehrere Periepheriegeräte aufnehmen, je nach deren Größe. Das Enc14/16 wird gern eingesetzt, um z.B. am Bein eines CM110, CM115 oder CM120 befestigt zu werden, wo das große Enc16/18 nicht hin passt.
Lesen Sie mehrThe ENC14/16's backplate is prepunched with one-inch-on-center holes suitable for attaching a datalogger, power supply, and a communications or measurement and control peripheral.
Color | White (Reflects solar radiation, reducing temperature gradients inside the enclosure without requiring a separate radiation shield.) |
Construction | Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps |
Enclosure Classification | NEMA 4X (before being modified for cable entry) |
Number of Cable-Entry Seals | 2 large, 2 medium, 2 small |
Dimensions |
|
Weight | 6 kg (13 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Number of FAQs related to ENC14/16: 16
Alle anzeigenWenige anzeigen
If you purchased a Stahlin enclosure from Campbell Scientific and it has a failed gasket, we can help you. We will need you to provide an image of the failed gasket, verify the size of your enclosure, and provide your contact information. We can then arrange to have a replacement gasket sent to you from Stahlin. For assistance, contact Technical Support at 435.227.9100.
The following information is applicable to many of Campbell Scientific’s standard enclosures and prewired enclosures.
Note: The procedure below will not work for torn or damaged seals.
To make a field repair to a loose gasket on an enclosure, first acquire an adhesive, such as standard Gorilla Glue, that is rated for use with polyurethane foam. The adhesive should be compatible with, and recommended for, use with polyurethane foam. Follow these steps:
Backplates are available in sizes designed to fit in Campbell Scientific enclosures: 10 x 12 in., 12 x 14 in., 14 x 16 in., and 16 x 18 in.