27814 CD100 Display und Tastatur zum Einbau im Gehäusedeckel

Überblick

Wenn Sie ein Gehäuse zusammen mit dem 27814 bestellen installiert Campbell Scientific das CD100 Display und Tastatur im Deckel des Gehäuses. Der Preis versteht sich inklusive CD100.

Lesen Sie mehr

Bilder

27814 (CD100 installed in an enclosure lid)
27814 (CD100 installed in an enclosure lid)
27814 (CD100 installed in an enclosure lid)
27814 (CD100 installed in an enclosure lid)
27814 (CD100 installed in an enclosure lid) and mounted to a pole (sold separately)

Technische Beschreibung

The CD100 keypad with display provides the same operation and functionality as the CR1000KD. It allows you to check the datalogger's status, to view or plot sensor readings and stored values, and to enter numeric data or change ports.

The design of the CD100’s 16-character keypad permits operation with a gloved hand. Its vacuum fluorescent display is responsive through a wide operating-temperature range, and can show 8 lines by 21 characters (64 by 128 pixels). The CD100 is both water- and dust-protected, providing an IP66 rating when installed in the enclosure lid.

Spezifikationen

Display 8 line x 21 character (64 x 128 pixel)
Keypad 16 key, alphanumeric
Power Requirements Powered from the data logger's CS I/O port
Water & Dust Ingress Protection Rating IP66 (when installed in enclosure lid)
Compliance CE compliant
Current Drain
  • negligible (0.02 mA) inactive
  • 140 mA (active)
Operating Temperature Range -45° to +85°C
Storage Temperature Range -50° to +85°C
Transit Temperature Range -60° to +85°C (1 hr)
Dimensions 17.5 x 13.7 x 3.6 cm (6.9 x 5.4 x 1.4 in.)
Weight < 0.5 kg (< 1 lb)

Kompatibel mit

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Datenlogger

Product Compatible Note
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR3000 The CR3000's integrated keyboard display is preferable for most situations. A special data logger OS is required to use the CR3000; contact Campbell Scientific for more information.
CR5000 (retired)
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Dokumente

Übereinstimmung mit Richtlinien u. Vorschriften