Datenkabel / MD9
Limited Availability ›
This product has limited availability. It will be replaced by: MD485. Some accessories, replacement parts, or services may still be available when it is no longer available.
MD9 Coax Multidrop Interface

Überblick

Effective 1 January 2004, the MD9 Multidrop Interface was generally replaced for new multidrop applications by the MD485 Multidrop Interface. However, the MD9 remains available for customers with existing MD9 networks.

The MD9 Multidrop Interface links a computer to as many as 200 dataloggers over a single coaxial cable. Each datalogger in the network is connected to an MD9 that has a unique, user-assigned address. Communication between the computer and a specific datalogger is routed through the MD9’s address allowing the rest of the network to remain in quiescent mode. Total coaxial cable length can be up to three miles; each MD9 in the network slightly reduces the maximum transmission distance.

Lesen Sie mehr

Bilder

Zugehörige Produkte

Technische Beschreibung

Effective 1 January 2004, the MD9 Multidrop Interface was generally replaced for new multidrop applications by the MD485 Multidrop Interface. The MD9 remains available for customers who have MD9 networks currently deployed in the field. MD9s and MD485s can NOT be used in the same network.

The MD9 Multidrop Interface links a central computer to up to 200 data loggers on a single coaxial cable. Total cable length can be up to 3 miles. At least two MD9s are required within a network.

Spezifikationen

Baud Rates 9600, 1200, 300 (hardware-selectable)
Current Drain
  • 1.2 mA (quiescent)
  • 80.0 mA (active)
Operating Voltage 5 Vdc (from the PS150 or SC532(A) interface)
Carrier Frequency 1.2 MHz
Operating Temperature Range
  • -25° to +50°C (standard)
  • -55° to +85°C (extended)
Dimensions 16.2 x 8.8 x 3.0 cm (6.4 x 3.5 x 1.2 in.) including connectors
Weight 227 g (8 oz)

Kompatibel mit

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Datenlogger

Product Compatible Note
CR1000 (retired) Requires LoggerNet 4.2 or higher.
CR200X (retired)
CR216X (retired)
CR3000 Requires LoggerNet 4.2 or higher.
CR5000 (retired)
CR800 (retired) Requires LoggerNet 4.2 or higher.
CR850 (retired) Requires LoggerNet 4.2 or higher.
CR9000X (retired)

Dokumente

Broschüren Produkte


FAQs für

Number of FAQs related to MD9: 1

  1. Yes, but only if all the other dataloggers are PakBus devices, such as the CR800, CR850, and CR1000.

Anwendungsbeispiele

California: Coastal Slope Monitoring
The North County Transit District (NCTD) of San Diego County, California, determined that three segments......lesen Sie mehr
Australia: Examining the Impacts of Carbon Dioxide and Climate Change
An experimental facility (OzFace) has been established in Townsville, Australia to examine the impacts of......lesen Sie mehr