Services Available |
---|
Der OBS-3A kombiniert unseren OBS-Sensor mit Sensoren für Temperatur, Druck und Leitfähigkeit. Der Mini-Datenlogger, Batterien und Elektronik befinden sich in einem Gehäuse, das in bis zu 300m Tiefe verwendet werden kann, abhängig vom Drucksensor.
(OBS® is a registered trademark of Campbell Scientific.)
Lesen Sie mehrThe heart of the OBS-3A monitoring system is an OBS sensor for measuring turbidity and suspended solids concentrations. This sensor detects near infrared (NIR) radiation scattered from suspended particles.
A fast-response, stainless steel-clad thermistor monitors temperature. Pressure is measured with a semiconductor piezoresistive strain gauge, and conductivity is measured with a four-electrode conduction-type cell. Working depths of the pressure sensor are selected as an option. (See the Ordering Info on the web page.)
The monitor uses HydroSci software running under Windows XP, 7, and 8.
Output | RS-232, RS-485 |
Maximum Submersion Depth | 300 m (984 ft) |
Connector | MCBH-8-FS, wet-pluggable |
Operating Temperature Range | 0° to 35°C |
Storage Temperature Range | -20° to +70°C |
Drift over Time | < 2% per year |
Drift over Temperature | 0.05% per °C |
Maximum Sample Size | 2048 |
Sampling Rate | 1 to 25 Hz (when connected to a PC) |
Maximum Data Rate |
|
Data Capacity | 8 MB |
Maximum Number of Data Lines | 200,000 |
Maximum Concentration Range |
|
PC Interfaces | RS-232/115 kbps, RS-485/115 kbps |
Battery Capacity | 18 Ahr |
Maximum Battery Life | 8,000 h |
Infrared Wavelength | 850 nm |
Pressure Measurement Range | 0 to 10, 20, 50, 100, or 200 m |
Turbidity Measurement Range | 0.4 to 4,000 NTU |
Conductivity Measurement Range | 0 to 65 mS/cm (40 PSU, o/oo) |
Concentration Accuracy |
|
Pressure Accuracy | ±0.5% of f.s. (where f.s. = 50, 100, or 200 dBar) |
Turbidity Accuracy | < 2% |
Temperature Accuracy | ±0.5°C |
Conductivity Accuracy | 1% |
Diameter | 7.6 cm (3.0 in.) |
Height | 36.2 cm (14.3 in.) |
Weight | 1.5 kg (3.4 lb) without batteries |
Campbell Scientific offers a choice of field cables used to connect the OBS-3A to a PC for system configuration. The cables differ in their length. The HydroSci support software can be downloaded.
HydroSci is used to configure and extract data from the CRS45X Recording Submersible Pressure Transducer and the OBS-3A Turbidity and Temperature Monitoring System.
Watch the Video Tutorial: Using HydroSci software with water-level recording sensors.
Adds Chinese language support for version 1.2 of HydroSci.
Note: Language support for the above listed version only.