RETIRED ›
This product is no longer available. Some accessories, replacement parts, or services may still be available.
CR-PVS1 RTU zur Bestimmung des Verschmutzungsgrads von Solarmodulen
Services Available

Überblick

Die Verschmutzung von Solarzellen und die dadurch verursachte Verringerung der Strommenge ist einer der wichtigesten Parameter zur Bestimmung der Leistung einer Solaranlage. Der CR-PVS1 Datenlogger zur Bestimmung des Verschmutzungsgrades versorgt Techniker mit den nötigen Daten um die Auswirkungen der Verschmutzung zu beurteilen. Der "Soiling loss Index" wird nach Standardmethoden aus der Solarindustrie  bestimmt, Rohdaten werden gespeichert und sind für zusätzliche Verarbeitung verfügbar.

Lesen Sie mehr

Funktionen und Vorteile

  • Real-time soiling loss index (SLI) measurement and control system
  • On-board data filtering that assures quality data
  • Daily average soiling loss index calculated
  • Modbus, DNP3, PakBus, data encryption, and Internet protocols supported
  • No programming necessary
  • Quick-deploy guide that simplifies installation

Bilder

Technische Beschreibung

The CR-PVS1 Soiling Loss Index RTU is designed to be at the heart of an independent soiling measurement station or as an add-on peripheral to any new or existing MET station. It supports many communication protocols such as Modbus, DNP3, PakBus, PakBus encryption, and several Internet protocols.

Deployment/configuration is simple and easy. The CR-PVS1 is delivered field ready and requires no programming. It will work with any user-supplied solar module to to 100 V open circuit and current up to 20 A, or it can be ordered with mini 20 W modules. Two highly accurate and rugged back-of-temperature sensors are included.

Soiling loss index is calculated from short-circuit and back-of-module temperature measurements of a reference PV module that is kept clean and a test PV module that is kept dirty. Measurements are made only when certain characteristics of global solar irradiance and temperature are met, avoiding any difference in soiling due to environmental instability, cloud influence, zenith angle of the sun, module current dependence on irradiance level, and to an extent, spectral effects. A quality factor is calculated to give the user some feedback on the number of qualified measurements.

From short-circuit current and back-of-module temperature, the effective irradiance of each module is calculated in accordance with IEC 60904 and a soiling loss index is calculated. A daily average soiling loss index is calculated, available for SCADA, and stored in on-board memory. For immediate feedback, a real-time soiling loss index and quality factor are available. Raw measured data are stored and available for the analyst or researcher looking to perform independent post-processing.

The procedure is straightforward and easily implemented with manual washing of the reference module, usually cleaned at the same time as the on-site pyranometer(s).

Short-Circuit Current Methodology

Numerous studies and documents have been published over several decades outlining and testing various methods in order to calculate losses due to soiling, along with their advantages and disadvantages. These studies show that the short-circuit current of a solar module is directly proportional to the light intensity, and it can be used as a reliable method to measure changes in light intensity from reaching the solar cells.

While other methods have been studied, such as I-V curve tracers or maximum power point trackers, these systems can provide minimal accuracy gains only under certain conditions that may not be practical in a field setting. The disadvantage to these systems is their cost and scalability, as they are typically a much more expensive and complicated endeavor.

The CR-PVS1 uses the short-circuit measurement method to provide end users with a simple, lower-cost solution that is more easily scalable and deployable in larger numbers on utility-scale solar projects using proven methods.

Spezifikationen

-NOTE- All CR-PVS1 RTUs are tested and guaranteed to meet electrical specifications in a standard -40° to +70°C non-condensing environment. Recalibration is recommended every three years. System configuration and critical specifications should be confirmed with Campbell Scientific before purchase.
Soiling Loss Index Can detect ~1%
Maximum Voltage 100 V
Maximum Current 20 A
Measurement Accuracy ~ 2 μV
Dimensions
  • 20.3 x 14 x 6.3 cm (8.0 x 5.5 x 2.5 in.) without mounts
  • 21.6 x 14 x 6.3 cm (8.5 x 5.5 x 2.5 in.) with mounts

Back-of-Module Temperature Measurements

Temperature Uncertainty for -40° to +70°C ±0.2°C tolerance
Temperature Uncertainty for 71° to 105°C ±0.5°C tolerance
Temperature Uncertainty for 106° to 135°C ±1°C tolerance
Time Constant in Air
  • 252 s (still air)
  • 25 s (surface)
Measurement Range -40° to +135°C
Steinhart-Hart Linearization Equation Error 0.0024°C (at -40°C) maximum

Short-Circuit Current Measurements

Maximum Operating Temperature +80°C
Shunt Accuracy ±0.25%

Communications

Default Configuration Modbus RTU
Internet Protocols PPP, ICMP/Ping, Auto-IP(APIPA), IPv6, UDP, TCP, TLS, DHCP Client, SLAAC, DNS Client, Telnet
Additional Protocols Supported PakBus, SDI-12, Modbus RTU, Modbus ASCII, Modbus TCP/IP, DNP3 (Custom user-definable over serial.)
Data File Formats CSV, XML, JSON, binary, encrypted
USB USB micro-B device only, 2.0 full-speed 12 Mbps, for computer connection
RS-232 Female RS-232, 9-pin interface

System

Clock Accuracy ±1 min per month
Clock Resolution 1 ms
Program Execution 100 ms to one day

Power Requirements

Charger Input (CHG) 16 to 32 Vdc, current limited at 0.9 A (power converter or solar panel input)
Internal Lithium Battery 3 V coin cell CR2016 (Energizer) for battery-backed clock. (6-year life with no external power source)
External Batteries (BAT) 12 Vdc, lead-acid 7 Ah battery (typical)
USB Power (USB) For programming and limited functionality
Typical Power Requirements
  • 1.5 mA (sleep)
  • 5 mA (active 1-Hz scan with analog measurements)

Compliance

CE All terminals tested to Class 4 levels (IEC 61000-4-5: 2013) for surge and (IEC 61000-4-2:2008) for ESD.
Shock & Vibration ASTM D4169-09
Protection IP30